Fix logic for rak12035 sensor default config and improve messaging (#9414)
* better logic to check if the RAK12035 soil sensor is calibrated, better log messaging if either of the default values were used. * . * changes to how default calibration is done and a message it the default calibration is used pointing to the actual calibration sketch so the user can find it and use it to improve accuracy. --------- Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
This commit is contained in:
@@ -26,7 +26,7 @@ bool RAK12035Sensor::initDevice(TwoWire *bus, ScanI2C::FoundDevice *dev)
|
||||
sensor.get_sensor_version(&data);
|
||||
if (data != 0) {
|
||||
LOG_INFO("Init sensor: %s", sensorName);
|
||||
LOG_INFO("RAK12035Sensor Init Succeed \nSensor1 Firmware version: %i, Sensor Name: %s", data, sensorName);
|
||||
LOG_INFO("RAK12035Sensor Init Succeed \nSensor Firmware version: %i, Sensor Name: %s", data, sensorName);
|
||||
status = true;
|
||||
sensor.sensor_sleep();
|
||||
RESTORE_3V3_POWER();
|
||||
@@ -49,33 +49,39 @@ void RAK12035Sensor::setup()
|
||||
// TODO:: Check for and run calibration check for up to 2 additional sensors if present.
|
||||
uint16_t zero_val = 0;
|
||||
uint16_t hundred_val = 0;
|
||||
uint16_t default_zero_val = 550;
|
||||
uint16_t default_hundred_val = 420;
|
||||
const uint16_t default_zero_val = 510;
|
||||
const uint16_t default_hundred_val = 390;
|
||||
|
||||
sensor.sensor_on();
|
||||
sensor.begin();
|
||||
delay(200);
|
||||
sensor.get_dry_cal(&zero_val);
|
||||
delay(200);
|
||||
sensor.get_wet_cal(&hundred_val);
|
||||
delay(200);
|
||||
if (zero_val == 0 || zero_val <= hundred_val) {
|
||||
LOG_INFO("Dry calibration value is %d", zero_val);
|
||||
LOG_INFO("Wet calibration value is %d", hundred_val);
|
||||
LOG_INFO("This does not make sense. You can recalibrate this sensor using the calibration sketch included here: "
|
||||
"https://github.com/RAKWireless/RAK12035_SoilMoisture.");
|
||||
LOG_INFO("For now, setting default calibration value for Dry Calibration: %d", default_zero_val);
|
||||
|
||||
bool calibrationReset = false;
|
||||
|
||||
if (zero_val == 0) {
|
||||
LOG_INFO("Dry calibration not set, using default: %d", default_zero_val);
|
||||
sensor.set_dry_cal(default_zero_val);
|
||||
sensor.get_dry_cal(&zero_val);
|
||||
LOG_INFO("Dry calibration reset complete. New value is %d", zero_val);
|
||||
delay(200);
|
||||
zero_val = default_zero_val;
|
||||
calibrationReset = true;
|
||||
}
|
||||
if (hundred_val == 0 || hundred_val >= zero_val) {
|
||||
LOG_INFO("Dry calibration value is %d", zero_val);
|
||||
LOG_INFO("Wet calibration value is %d", hundred_val);
|
||||
LOG_INFO("This does not make sense. You can recalibrate this sensor using the calibration sketch included here: "
|
||||
"https://github.com/RAKWireless/RAK12035_SoilMoisture.");
|
||||
LOG_INFO("For now, setting default calibration value for Wet Calibration: %d", default_hundred_val);
|
||||
LOG_INFO("Wet calibration not set, using default: %d", default_hundred_val);
|
||||
sensor.set_wet_cal(default_hundred_val);
|
||||
sensor.get_wet_cal(&hundred_val);
|
||||
LOG_INFO("Wet calibration reset complete. New value is %d", hundred_val);
|
||||
delay(200);
|
||||
hundred_val = default_hundred_val;
|
||||
calibrationReset = true;
|
||||
}
|
||||
if (calibrationReset) {
|
||||
LOG_INFO("Default calibration values applied. Consider running the calibration sketch for better accuracy: "
|
||||
"https://github.com/RAKWireless/RAK12035_SoilMoisture");
|
||||
}
|
||||
|
||||
LOG_INFO("Dry calibration value: %d, Wet calibration value: %d", zero_val, hundred_val);
|
||||
sensor.sensor_sleep();
|
||||
RESTORE_3V3_POWER();
|
||||
delay(200);
|
||||
|
||||