mirror of
https://github.com/meshtastic/firmware.git
synced 2025-12-13 22:32:27 +00:00
Fix Station G2 Lora Power Settings (#8273)
* Force coverage tests to run in simulation mode
* Revert "Force coverage tests to run in simulation mode"
This reverts commit e4ec719e6f.
* Fix Station G2 Lora Power Settings
In #8107 we introduced the ability to specify gain values for
non-linear power amplifiers.
This patch adds appropriate values for the Station G2, based on
the table at https://wiki.uniteng.com/en/meshtastic/station-g2#summary-for-lora-power-amplifier-conduction-test
Fixes https://github.com/meshtastic/firmware/issues/7239
---------
Co-authored-by: Austin Lane <vidplace7@gmail.com>
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
This commit is contained in:
committed by
Jonathan Bennett
parent
f99747180e
commit
30d6962e79
@@ -126,6 +126,11 @@ along with this program. If not, see <http://www.gnu.org/licenses/>.
|
||||
#define TX_GAIN_LORA 11, 11, 11, 11, 11, 11, 11, 11, 11, 11, 11, 11, 11, 11, 11, 11, 10, 10, 9, 9, 8, 7
|
||||
#endif
|
||||
|
||||
#ifdef STATION_G2
|
||||
#define NUM_PA_POINTS 19
|
||||
#define TX_GAIN_LORA 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 19, 19, 18, 18
|
||||
#endif
|
||||
|
||||
// Default system gain to 0 if not defined
|
||||
#ifndef TX_GAIN_LORA
|
||||
#define TX_GAIN_LORA 0
|
||||
|
||||
Reference in New Issue