mirror of
https://github.com/meshtastic/firmware.git
synced 2025-12-30 22:50:57 +00:00
'Station-g1-patch1'
This commit is contained in:
@@ -156,8 +156,21 @@ class AnalogBatteryLevel : public HasBatteryLevel
|
||||
/// If we see a battery voltage higher than physics allows - assume charger is pumping
|
||||
/// in power
|
||||
|
||||
#ifndef BAT_FULLVOLT
|
||||
#define BAT_FULLVOLT 4200
|
||||
#endif
|
||||
#ifndef BAT_EMPTYVOLT
|
||||
#define BAT_EMPTYVOLT 3270
|
||||
#endif
|
||||
#ifndef BAT_CHARGINGVOLT
|
||||
#define BAT_CHARGINGVOLT 4210
|
||||
#endif
|
||||
#ifndef BAT_NOBATVOLT
|
||||
#define BAT_NOBATVOLT 2230
|
||||
#endif
|
||||
|
||||
/// For heltecs with no battery connected, the measured voltage is 2204, so raising to 2230 from 2100
|
||||
const float fullVolt = 4200, emptyVolt = 3270, chargingVolt = 4210, noBatVolt = 2230;
|
||||
const float fullVolt = BAT_FULLVOLT, emptyVolt = BAT_EMPTYVOLT, chargingVolt = BAT_CHARGINGVOLT, noBatVolt = BAT_NOBATVOLT;
|
||||
float last_read_value = 0.0;
|
||||
uint32_t last_read_time_ms = 0;
|
||||
};
|
||||
|
||||
Reference in New Issue