Fix STM32WL TCXO setting; enable logs and modules (#6063)

Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
This commit is contained in:
GUVWAF
2025-02-15 16:06:10 +01:00
committed by GitHub
parent 2f6cd02111
commit 27fea5fc07
3 changed files with 12 additions and 6 deletions

View File

@@ -18,6 +18,9 @@ bool STM32WLE5JCInterface::init()
{
RadioLibInterface::init();
// https://github.com/Seeed-Studio/LoRaWan-E5-Node/blob/main/Middlewares/Third_Party/SubGHz_Phy/stm32_radio_driver/radio_driver.c
setTCXOVoltage(1.7);
lora.setRfSwitchTable(rfswitch_pins, rfswitch_table);
if (power > STM32WLx_MAX_POWER) // This chip has lower power limits than some
@@ -39,4 +42,4 @@ bool STM32WLE5JCInterface::init()
return res == RADIOLIB_ERR_NONE;
}
#endif // ARCH_STM32WL
#endif // ARCH_STM32WL

View File

@@ -16,9 +16,6 @@ class STM32WLE5JCInterface : public SX126xInterface<STM32WLx>
virtual bool init() override;
};
// https://github.com/Seeed-Studio/LoRaWan-E5-Node/blob/main/Middlewares/Third_Party/SubGHz_Phy/stm32_radio_driver/radio_driver.c
static const float tcxoVoltage = 1.7;
/* https://wiki.seeedstudio.com/LoRa-E5_STM32WLE5JC_Module/
* Wio-E5 module ONLY transmits through RFO_HP
* Receive: PA4=1, PA5=0